Detailed product view
Part number: 100095

Testomat 2000® determines water hardness, carbonate hardness, p-value, minus m-value

Measuring parameter:
Water hardness | Carbonate hardness | p-value | minus m-value
Measuring range:
0,05-25 °dH | 0,5-20 °dH | 1-15 mmol/l | 0,05-0,5 mmol/l
Field of application:
Universal for water treatment plants | Allowed for boiler houses | Certificate: type-test approval mark No TÜV.WÜH.16-002
Menu navigation:
Dutch, English, France, German, Italian, Polish
Accessories:
Optional:
• Plug-in card RS 910 for printer connection
• Plug-in card SK 910 for electricity interface 0/4-20 mA, galvanically isolated
• Booster Pump
• Data Logger for Testomat 2000®

Hints:

Find the new TüV test-type approval certificate in the manual (download via data sheet)!

Product description (Testomat 2000® determines water hardness, carbonate hardness, p-value, minus m-value):

The Testomat 2000® automatically determines water hardness, carbonate hardness, the p-value or the minus m-value via titration. It is ideal for monitoring the water quality of water treatment, water blending and drinking-water plants. Monitoring and quality control of softening plants with and without blending (Testomat 2000® reagent TH 2005–2250) Monitoring and quality control of decarbonisation plants (Testomat 2000® reagent TC 2050–2100) Measuring acidic values in decarbonisation and desalination plants (Testomat 2000® reagent TM 2005) Monitoring of steam boilers (Testomat 2000® reagent TP 2100).

Performance profile:
• 4-line LCD display for text display and the self-explanatory, menudriven operating interface
• Accurate titration via piston-dosing pump
• Reliable low maintenance operation
• Minimal reagent and water consumption
• Programmable hardness unit in °dH, °f, ppm, CaCO 3 and mmol/l
• Two adjustable limit values with programmable switch functions
• Analysis initiation:
– dynamic
– automatic interval operation (0–99 min.)
– quality-dependent (impulse water meter)
– external initiation and suppression
• The monitoring of the analysis run and error message, e.g. low water pressure
• Reagent storage bottle 500 ml for extended operating periods
• All parts in contact with water or reagent are made of a corrosionresistant material

 

Technical data:
Power Consumption: max. 30 VA
Protection class: IP 65
Ambient Temperature: 10–45 °C (50-113 °F)
Water Temperature: 10–40 °C (50-104 °F)
Operating Pressure: 0.3–8 bar
Weight: approx. 9.5 kg
Dimensions (W x H x D): 380 x 480 x 280 mm

 

Menu Navigation and Reference:

24 V/50-60 HZ: German 100090; English 100091; French 100092;Italian 100093; Polish 100094; Dutch 100011

115 V/50-60 HZ : German100100; English100101; French100102; Italian100103; Polish100104; Dutch100012

230 V/50-60 HZ: German100095; English100096; French100097; Italian100098; Polish100099; Dutch100013

Product version (Testomat 2000® determines water hardness, carbonate hardness, p-value, minus m-value)

Testomat_2000_1

Testomat 2000® THCL determines the Content of total chlorine | Part number: 100270

Measuring parameter: Total Chlorine | Water hardness
Measuring range: 0,00-0,99 mg/l and 1,0-2,5 mg/l | 0,25-2,5 °dH
Field of application: Multi-function instrument for water hardness and chlorine (DPD) for monitoring of reverse-osmosis plants | The protection of reverse osmosis membranes against blocking due to hardness and against destruction due to a high chlorine content. | Monitoring of softener and chlorination plants for drinking water or swimming pools

Testomat_2000_1

Testomat 2000® V | Part number: 100180

Measuring parameter: Water hardness | Carbonate hardness
Measuring range: 1,0–25,0 °dH Wasserhärte | 1,0–20,0 °dH Carbonathärte |
Field of application: Water blending

Testomat_2000_1

Testomat 2000® SO3 | Part number: 100350

Measuring parameter: Sulfite
Measuring range: (resolution) 0.0-9.9 mg/l and 10-20 mg/l
Field of application: Monitoring of surplus of oxygen binder sulfite | Monitoring of sulfite for oxygen-binding in boiler feed water

Testomat_2000_1

Testomat 2000® self clean | Part number: 100380

Measuring parameter: Water hardness | Carbonate hardness | p-value | minus m-value
Measuring range: 0,05-25 °dH | 0,5-20 °dH | 1-15 mmol/l | 0,05-0,5 mmol/l
Field of application: Automatic cleaning the measuring chamber

Testomat_2000_1

Testomat 2000® Fe Online-Analysic technics for monitoring the content of dissolved iron (II) + (III) | Part number: 100150

Measuring parameter: iron (Fe(II) / Fe (III)
Measuring range: (resolution) 0.00-0.65 mg/l and 0.7-1,0 mg/l iron-II and iron-lll
Field of application: Monitoring of surplus of oxygen binder sulphite | The monitoring of de-ironing plants | Controlling industrial or drinking-water currents

Testomat_2000_CN_

Testomat 2000® DUO CN | Part number: 110221

Measuring parameter: Water hardness | Carbonate hardness | p-value | minus m-value
Measuring range: 0,05-25 °dH Wasserhärte | 0,5-20 °dH Carbonathärte | 1-15 mmol/l p-Wert | 0,05-0,5 mmol/l minus m-Wert
Field of application: Controlling of two measuring points with different reagents | Languages: Mandarin / English

Testomat_2000_1

Testomat 2000® DUO Online-Analysis technics | Part number: 100290

Measuring parameter: Water hardness | Carbonate hardness | p-value | minus m-value
Measuring range: 0,05-25 °dH Wasserhärte | 0,5-20 °dH Carbonathärte | 1-15 mmol/l p-Wert | 0,05-0,5 mmol/l minus m-Wert
Field of application: Controlling of two measuring points with different reagents

Testomat_2000_1

Testomat 2000® CrVI | Part number: 100310

Measuring parameter: chromate | chromium-VI
Measuring range: 0-2,0 mg/l chromate | 0-1,0 mg/l chromium VI
Field of application: Process control of waste water in galvanic industry | Monitoring of chromate content of galvanic waste water | Controlling of process water in the electroplating/metal industry

Testomat_2000_1

Testomat 2000® CLT | Part number: 100130

Measuring parameter: - Total chlorine | - Free chlorine
Measuring range: 0.00-0.99 mg/l and 1.0--2,5 mg/l total chlorine | 0.00-0.99 mg/l and 1.0-2.5 mg/l free chlorine
Field of application: DPD-method for swimming pool and drinking water control | The monitoring of chlorination plants for drinking water | The monitoring of chlorination plants for swimming pools | The provision of protection for reverse osmosis membranes | The controlling of chlorine biocides and conditioning agents

Testomat_2000_1

Testomat 2000® CLF | Part number: 100230

Measuring parameter: Free Chlorine
Measuring range: 0.00-0.99 mg/l and1.0-2,5 mg/l
Field of application: DPD-method for swimming pool and drinking water control | Chlorination monitoring for drinking-water or swimming pools | Provides protection for reverse osmosis membranes | The controlling of chlorine biocides and conditioning agents

Testomat_2000

Testomat 2000® CLO2 | Part number: 100500

Measuring parameter: Chlordioxid
Measuring range: 0.00-1,88 mg/l and 1,9-4,7 mg/l
Field of application: Monitoring the content of chlorine dioxide

Testomat_2000_1

Testomat 2000® CAL | Part number: 100210

Measuring parameter: Water hardness | Carbonate hardness | p-value | minus m-value
Measuring range: 0,05-25 °dH | 0,5-20 °dH | 1-15 mmol/l | 0,05-0,5 mmol/l
Field of application: Automatic calibration function

Testomat_2000_1

Testomat 2000® Br2 | Part number: 100520

Measuring parameter: Bromine
Measuring range: (resolution) | 0,02 mg/I (ppm) im Bereich 0 – 2,23 mg/I (ppm) | 0,2 mg/I (ppm) im Bereich 2,3 – 5,6 mg/I (ppm)
Field of application: Monitoring the content of bromine | Monitoring the dosing of the disinfectant

Testomat_2000_1

Testomat 2000® Antox | Part number: 100440

Measuring parameter: Water hardness | Carbonate hardness | p-value | minus m-value
Measuring range: 0,05-25 °dH | 0,5-20 °dH | 1-15 mmol/l | 0,05-0,5 mmol/l
Field of application: Dosing of reducing agent at high concentration of oxidising agent
Equipment configuration: Power Consumption: max. 30 VA
Protection class: IP 65
Ambient Temperature: 10–45 °C (50-113 °F)
Water Temperature: 10–40 °C (50-104 °F)
Operating Pressure: 0.3–8 bar
Weight: approx. 9.5 kg

Testomat_2000

Testomat 2000® CLT self clean | Part number: 100245

Measuring parameter: Total Chlorine
Measuring range: 0.00-0.99 mg/l, 1.0-2.5 mg/l Total Chlorine
Field of application: Monitoring of disinfectant dosing in the drinking water field | Water treatment at dialysis centers

Testomat_2000_CN_

Testomat 2000® CN | Part number: 110212

Measuring parameter: Water hardness | Carbonate hardness | p-value | minus m-value
Measuring range: 0,05-25 °dH | 0,5-20 °dH | 1-15 mmol/l | 0,05-0,5 mmol/l
Field of application: Special equipment for the Chinese Market | Languages: Mandarin / English | Universal for water treatment plants | Allowed for boiler houses



 
 
 
To the top